SEC-600 and SE-600 Systems

SEC-600/SE-600 Series Systems

High Vacuum Deposition Systems

In all SE/SEC-Series systems, the baseplate (typically 20 inches) accommodates up to 15 feedthroughs for instrumentation, control and rotary motion. SE/SEC-600 systems are most often equipped with a 19.5″ diameter bell jar and Planetary Fixturing having a capacity of 18 4″ wafers. The average pumpdown time of less than 30 minutes allows throughput in excess of 54 wafers per hour.

Ultimate vacuum: 10 -8 torr range

  • Cryogenic pump: 8″
  • Mechanical pump: 23-57 CFM, dual stage
  • Cold trap: 2.5 liter capacity, 200 sq. inches of surface area, 10 hours holding time
  • Water baffle: Optically dense, chevron baffle
  • High vacuum valve: 7-3/4″ I.D., seals vertically
  • Foreline/Roughing valves: 3″ I.D.
  • Valve actuation: Electro-pneumatic (all vacuum valves)
  • Valve sequencing: Manual and automatic (Auto-Tech II)
  • Ionization gauge control: Dual ionization gauge tube, auto ranging with dual convectron positions.
  • Dimensions: 79″H x 43″W x 37″D
  • Weight: 1,200 pounds
  • Utilities
    • Electrical: 208/10/70A/4-wire connection with ground (3 phase, 5-wire also available)
    • Water: 10 GPM (minimum)
    • Air: 90-110 PSIG

  • Options:
    • Diffusion pump: 2400 liter/second, 6″ normal
    • Process chamber: 19.5″ diameter x 30″ H, ambient or water-cooled (larger bell jars available)
    • Fixturing: Variety of fixturing options: planetary, clamshell, or custom.
    • Baseplate: 20″ or 26″ diameter, 7-3/4″ pumping port
    • Substrate heat:2-10 kW
    • Sources: Any commercially available source, including single and multiple beam, CHA’s resistance and sputtering sources.
    • Hoists: Motorized hoist assembly, 1/4HP motor
    • LN2 Level Control: Automatically maintains liquid level in cryogenic trap.
    • Sieve trap: Molecular sieve trap prevents migration or backstreaming of mechanical pump oil into the system.
    • RGA port: 2.75 O.D. flange located in base plate of system provides integration of a residual gas analyzer.
    • Automatic deposition control: Process controller provides fully automatic deposition sequence.
    • Automatic gun rotation control: Positions the crucibles of a turret-type electron beam source.
    • Shutter/shutter control: Different design shutters can be incorporated depending on source configuration and number.
Scroll to Top